Purpose
To measure the total volume of product loaded or unloaded by measuring the revolutions of the meter it is mounted on. Can be mounted directly on top of meter types SAMPI, LC, Neptune, SBM, Smith or remotely mounted using the Liquip ERP100 remote pulser on the meter.
Operation
During delivery, flowrate, volume delivered, volume remaining, temperature reading and meter number can be displayed. When delivery is finished a delivery report or management ticket can be printed with the touch of a button
Technical Data
Size: 206X206X131mm, Weight 1.6kg
Displays: 8 alphanumeric character dot-matrix LCD for delivery
Power: 9 to 30 Vdc @ 350mA max – polarity protected
Temperature Compensation: -15 to +55 deg C for LPG, -20 to +60 deg C for other products
Product Density 0.500 to 0.600 for LPG, 0.653 to 1.075 for other products
Variants
EMH500 series with Preset